Certifications
- DUST IGNITION PROTECTED
- CLEANING MACHINES For Hazardous Locations (Classes C1618 01 & C1618 81)
- Division 2, Class II, Groups F & G
- Certified Zone 22 Hazardous Areas / Dust Group IIIC (Conductive Dusts)
- IECEx 3rd Party Certified
- Ex h tc IIIC T200°C (T85°C for BLSD version) Dc IP6X IECEx LCIE 15.0048
This model can be used to Recover Combustible/Conductive Dusts in Hazardous Locations Division 2 and Zone 22 Dust Group IIIC:
Group F Conductive Carbonaceous Dust (carbon black, coal, coke dust, etc)
Group G All flour Dust (grain, flour, starch, sugar, wood, plastic, chemical dust, etc)
Group IIIC Conductive Dust Zone 22 (as per International Standards)
Complies with NFPA 77 "Recommended Practice on Static Electricity"
Features
- Longer life brushless motor available. Always with 4 x H14 HEPA filters
- Ideal for housekeeping and general cleaning
- By-pass Ametek® long life motor
- Includes 4 HEPA filters. Class H14. Individually factory tested
- Manual Filter Shaker (MFS) with static dissipative Teflon laminated main cloth filter assembly
- Detachable recovery tank (DT) for easy disposal of recovered materials
- Material to be recovered within a conductive poly liner recovery bag for easy disposal
ESD Safe Vacuum Systems for Hazardous Locations are designed to prevent ignition hazards.
We use metal parts or Static Dissipative Powder Coating to prevent Electrostatic Discharge (ESD)
More information in downloads