Certifications
ATEX 3rd Party Certified
0081
II 1/3D
ATEX
External: Ex h tc IIIC T200°C (T85°C for BLSD version) Dc IP6X
Internal: Ex h IIIC T200°C (T85°C for BLSD version) Da
LCIE 15 ATEX 3061
This model can be used to Recover Combustible Dusts such as Dust Groups :
IIIA Combustible Flyings (lints of cotton, wood chips, etc.)
IIIB Non-Conductive Dusts (flour dust, grain dust, flour, sugar, starch, wood, plastic, carbonaceous dusts, coal, carbon black)
IIIC Conductive Dusts (combustible metal dust, aluminum, magnesium, commercial alloys)
IECEx 3rd Party Certified
External: Ex h tc IIIC T200°C (T85°C for BLSD version) Dc IP6X
Internal: Ex h IIIC T200°C (T85°C for BLSD version) Da
Dry Recovery Only
Features
- Ideal for housekeeping and general cleaning
- Includes 4 HEPA filters. Class H14. Individually factory tested
- Heavy duty 2-stage by-pass motor
- Longer life brushless motor available. Always with 4 x H14 HEPA filters
- Material to be recovered within a conductive cloth recovery bag
- Includes an indicator light to warn of vacuum blockage
- Recovery tank made of stainless steel SAE 430. Recovery tank made of stainless steel SAE 304 is also available
- Includes a complete static dissipative tool kit
ESD Safe Vacuum Systems for Hazardous Locations are designed to prevent ignition hazards.
We use metal parts or Static Dissipative Powder Coating to prevent Electrostatic Discharge (ESD)
More information in downloads