Certifications
ATEX 3rd Party Certified
0081
II 2GD
ATEX
- Ex d IIA T3 Gb
- Ex t IIIC T200°C Db IP6X
- LCIE 03 ATEX 6297
ATEX Zone 1/21
Pharma, Combustible Dust - Dry Recovery Only
GUARANTEED or the Safe Recovery of Combustible/Conductive Dusts
ESD Safe Vacuum Systems for Hazardous Locations are designed to prevent ignition hazards.
We use metal parts or Static Dissipative Powder Coating to prevent Electrostatic Discharge (ESD)
Features
- Legally certified explosion proof/dust ignition proof
- Less than 10 ohms of resistivity
- HEPA filter with an efficiency of 99.995% at 0.3 micron. Tested IEST-RP-CC001. H14 by MPPS method as per EN 1822 and OSHA compliant. All of our HEPA vacuum systems are aerosol leak tested before leaving our facility - optional
- Cleanroom compatible with ISO Class 4 (former Class 10). Can be used in the Pharmaceutical industry
- For general cleanup in hazardous locations
- Single phase explosion proof/dust ignition proof motor
- For dry recovery only
- All stainless steel SAE 304 construction
- Static dissipative poly liner and clip for the easy and safe disposal of recovered materials - available
- Mounted on a 4-wheel dolly for easy maneuverability. Dolly has static dissipative wheels
- Complete static dissipative tool kit is available
More information in Downloads